Com Power LI-115 LISN Network Equipment
Follow us for the latest equipment specials.
Refurbished Com Power LI-115
Sell Equipment Repairs Add to cart E-mail this page Alert me when this goes on sale
Com Power LI-115 Details
Com Power LI-115
30 MHz, Line Impedance Stabilization Network.
This item is no
longer manufactured new, the replacement is the Com-Power LIN-115.
The Com-Power LI-115 Line Impedance Stabilization Networks (LISNs) is utilized during single phase conducted emissions testing per FCC, CISPR and European norms, and meet the impedance requirements called out in these specifications.
The LI 115 LISN provides input power line impedance to the equipment under test (EUT) that is constant and independent of the line impedance of the external power source during conducted emissions testing.
The LI115 has an aluminum enclosure that minimizes radio frequency interference which can compromise test results and use air-core coils to prevent saturation and permeability variation.
Features:
- Frequency range: 150 kHz or 0.15 MHz - 30 MHz
- Inductor uH: 50
- Current Rating Amps: 15
- EMI Test Specification: FCC, CISPR, EN, AS/NZL
- Coils matched to application
- Air core coils
- Individually calibrated