Leader LT4442 Video Equipment
Follow us for the latest equipment specials.
New Leader LT4442
Sell Equipment Repairs Add to cart E-mail this page Alert me when this goes on sale
Leader LT4442 Details
Leader LT4442
Auto Changeover
The LT 4442 is a changeover unit that automatically switches the signal from the primary signal to the backup signal when problems are detected in the primary signal. Two systems of input signals (primary and backup) are connected to the LT 4442, and the LT 4442 detects errors in the amplitude of the primary input signal.
A single LT 4442 provides 11 channels. Depending on the configuration of the internal switches, SDI (channels 1 to 3 only), analog black burst, tri-level sync, AES/EBU digital audio, and word-clock signals can be received by the channels.
Relays are used to switch channels 1 to 3. Electronic switches are used to switch channels 4 to 11. In addition to the electronic switches, channels 4 to 11 are also equipped with high-speed, error detection circuits. When trouble such as a signal interruption occurs, the LT 4442 can quickly switch to a signal that has a small amount of glitches. (NTSC or PAL analog black burst, trilevel sync, AES/EBU digital audio, and word-clock signals can be received.)
If a switch occurs from a primary signal to a backup signal, the LT 4442 lights the panel LED that indicates the channel that is causing the problem.
- Provides 11 channels (a single channel consists of a primary input, a backup input, and an output) on a single LT 4442.
- The LT 4442 uses electronic switches for switching channels 4 to 11. It also uses high-speed detection circuits for detecting errors. These enable the LT 4442 to switch to a backup signal with barely any disturbances shown on the screen when problems such as interruptions occur in the primary signal.
- The channel 9 and 10 inputs are dedicated inputs for AES/EBU digital audio signals.
- The channel 11 input is a dedicated input for word-clock signals. The channel receives TTL signals and transmits +5 V CMOS signals.
- The delay for starting the error monitoring at power up can be set to FAST or SLOW depending on the rise time of the system signal source that the LT 4442 is connected to.
- By using the internal preset switches, you can switch between the level detection of SDI (only supported on channels 1 to 3), NTSC or PAL analog black burst, and HD analog tri-level sync signals.
- AES/EBU digital audio and word-clock signals are received through dedicated connectors.
- AES/EBU digital audio and word-clock signals are received through dedicated connectors.
- When a signal level error is detected, the LT 4442 lights the error LED on the panel as well as the panel LED that indicates the input channel that is causing the problem. This feature allows quick investigation of the problem.
- The depth of the LT 4442 matches the LT 4400(Multiformat Video Generator). This enables you to construct a system that is 2U in size by combining the LT 4442 with the LT 4400.