Wayne Kerr 3260B General Analyzers
Follow us for the latest equipment specials.
New Wayne Kerr 3260B
Call 1-800-615-8378 or 407-804-1299 for more information
Sell Equipment Repairs Add to cart E-mail this page Alert me when this goes on sale
Wayne Kerr 3260B Details
Wayne Kerr 3260B
Precision Magnetics Analyzer 20Hz-3MHz
Fast measurement speed - up to 20 measurements per second
0.1% basic accuracy
Up to 125 A of DC bias current
Telecom measurement functions
Analysis mode with graphical displays
Comprehensive measurement functions including leakage tests
Straightforward intuitive operation
Print test results
IEEE 488GPIB control with LabVIEW™ driver
At the design stage of component development it is vitally important to understand how the component performs under different operating conditions. This might include operation at diverse frequencies, AC drive levels or DC bias currents.
The 3260B Precision Magnetics Analyzer can plot any of the measurement functions, such as inductance (L) or impedance (Z), (including secondary term) against frequency, AC drive level or DC bias current.
Frequency sweeps within the range 20 Hz to 3 MHz can be selected. There is a choice of either linear or logarithmic frequency displays.
3260B is especially suitable for measuring parameters on telecom transformers.
The selected measurement parameter and its secondary value are presented graphically. AC drive levels can be set between 1 mV and 10 V. DC bias current can be set from 1 mA to 1 A internally. Using external 3265B 25 A DC Bias Units bias currents can be set to a maximum of 125 A.
Measure Insertion Loss and Return Loss on telecom transformers
With the dramatic growth of PCs connected to the telephone system for Internet access has come the requirement to measure Insertion Loss (IL) and Return Loss (RL) of line matching transformers.
The 3260B Precision Magnetics Analyzer not only measures IL and RL has this capability. but the instrument also allows the user to enter the values for terminating resistance or impedance, if complex, and to select a damped network or blocking capacitor if required.
Specification summary
Measurement functions Z, Ø, L, C, Rac, Rdc, Q, D
Turns Ratio
Primary and secondary Leakage Inductance
Interwinding Capacitance
Resonant Frequency
Frequency ranges 20 Hz to 3 MHz
Basic accuracy 0.1%
Mode Analysis (graphing)
Telecom
Multi Frequency
Sequence
DC bias current 1 mA to 1 A (internal)
Up to 125 A (using five 3265B DC Bias Units)
Interface GPIB
Measurement speed Up to 20 measurements/sec
Printed output of test results
Using the parallel Centronics interface the user can directly print test results including graphs for further analysis and archiving.
In addition, via the IEEE488 GPIB interface, the instrument can be controlled from a PC and results can be read back for analysis and storage. LabVIEW™ drivers are available upon request or may be downloaded from this website providing a base from which a user can develop a specific test application.
Bin sort
The bin sorting function allows component manufacturers to sort components in up to ten bins. Sorting is carried out either by absolute values or by percentage of values.