AEMC Instruments 6472 KIT 150FT Ground Earth Testers
Follow us for the latest equipment specials.
Refurbished AEMC Instruments 6472 KIT 150FT
Call 1-800-615-8378 or 407-804-1299 for more information
Sell Equipment Repairs Add to cart E-mail this page Alert me when this goes on sale
AEMC Instruments 6472 KIT 150FT Details
AEMC Instruments 6472 KIT 150FT
6472Kit-150ft Multi-Function Ground Resistance Testers
The Model 6472 is available in complete kit form, which includes the instrument, two 150 ft color-coded leads on spools (red and blue), one 30 ft lead (green), two 14.5" T-shaped auxiliary ground electrodes, one set of five spaded lugs, 100 ft tape measure and carrying bag.
Features
3-Point Fall-of-Potential measurement
3-Point earth coupling measurement
Manual or automatic frequency scan from 40 to 513Hz for test accuracy in electrically noisy environments
Earth coupling testing
Selectable test voltage 16 or 32V up to 250mA test current
4-Point soil resistivity measurement with automatic calculation of Rho and user selection of Wenner or Schlumberger test method
2- and 4-Wire DC resistance measurement (Bond testing) with automatic polarity reversal
Ground Resistance with 2 clamps (no auxiliary rods)
Ground Resistance of Pylons with the GroundFlex Adapter Model 6474 and GroundFlex sensors allow the system to measure leakage current and ground resistance of tower legs without disconnecting the overhead ground conductor.
Includes DataView software for data storage, real-time display, analysis, report generation and system configuration
Auto-off power management
Automatic recognition of all electrode connections and their resistance value
Stores up to 512 complete test results in internal memory
Optically isolated USB communication
Rechargeable NiMH batteries from wall charger or vehicle power
Rugged dustproof and rainproof field
Applications
3-Point measurements of resistance to ground of ground rods and grids. 3-Point measurements are used when electrode or grid can be easily disconnected.
4-Point tests or soil resistivity measurements. Locating areas of lowest soil resistivity is essential for achieving an economical grounding installation.
Touch and step potential testing measurements. These tests are recommended when the ground cannot be disconnected, where ground faults are highly likely to occur, or when the “footprint” of grounded equipment (the outline of the part of equipment in contact with earth) is comparable to the size of the ground to be tested.
2- or 4-Wire tests for continuity tests on bonding or on grounding systems. Test is a DC resistive test using 250mA or more and is used to check bonding of all connection points on the ground system.
Earth coupling measurement and display. Used to estimate the influence of two earth resistance systems that are not connected to each other.