Krohn Hite MV106 Voltage Calibrators
Follow us for the latest equipment specials.
Refurbished Krohn Hite MV106
Sell Equipment Repairs Add to cart E-mail this page Alert me when this goes on sale
Krohn Hite MV106 Details
Krohn Hite MV106
The Models MV106 is a precision voltage standards/sources that are highly versatile references designed to meet the needs of computer systems, production line testing, automated calibration systems and standards laboratories. The MV106 provides 3 voltage ranges which include 10mV, 100mV and 10V. Resolution is 0.01 V.
SPECIFICATIONS
Output: 10V, ±11.11110Vdc; 100mV, ±111.1110mVdc; 10mV, ±11.11110mVdc Resolution (1ppm): 10V, 10 V; 100mV, 0.1 V; 10mV, 0.01 V Output Accuracy (2 Methods) Calibration Accuracy: ±(0.003% of setting + 0.0005% of range + 2 V); at standard conditions at time of calibration; nominal temperature of 23 C ±1 C at <70% relative humidity; nominal line voltage 117Vac at constant external load. Limit-of-Error (Worst Case Method): ±(0.005% of setting + 0.00075% of range + 2 V). This method includes all peripheral, additive specification, (i.e., error for line and load changes, ambient temperature changes and stability). Calibration cycle, 1 full year. Stability (non-additive): 1hr., ±(0.0005% of range + 2 V); 8hrs., ±(0.001% of range + 2 V); 1yr., ±(0.0025% of range + 2 V) Ripple & Noise, rms, 0.8Hz to 100kHz (non-additive): 10V, 50 V; 100mV, 1 V; 10mV, 0.5 V Output Current (with remote sensing) See Output Impedance: 10V, 50mA; 100mV, into RL>100k ohms; 10mV, into RL>100k ohms Line & Load Regulation (non-additive): ±0.0005% Output Impedance (All Zout are fixed constants): 10V, 0.03 ohms; 100mV, 3 ohms; 10mV, 3 ohms
GENERAL Temperature: Calibration, 23 C ±1 C; ambient, 20 C to 30 C; operating limit, –10 C to 50 C; storage, –40 C to 85 C. Temperature Coefficient: Ambient, ±0.0005%/ C; operating limit, ±0.001%/ C. Settling Time: Step change, 300ms; range change, 700ms. Common Mode Rejection: 120dB, dc to 400Hz. Isolation: Either terminal may be floated 500Vdc with respect to chassis ground; 1G ohm, 20pF. Power Requirements: Selectable 115V or 220Vac ±10%; line frequency, 50Hz to 400Hz; power, 5 watts. Circuit Condition Indicator: Front panel indicator for short-circuit, overload, over-voltage condition, low line voltage or malfunction. Protection: Short-circuit and overload protection automatic recovery, over voltage protection up to 150Vdc. Dimensions: 5.22" (13.3cm) high, 17" (43.2cm) wide, 10.9" (27.7cm) deep. Weight: 13 lbs. (6.0kg) net; 17 lbs. (7.7kg) shipping.
MISCELLANEOUS Certification: Certificate of Compliance traceable to the U.S. N.I.S.T. Warranty: One year, includes accuracy and stability. Evaluation: Instruments are available for engineering evaluation. Contact our local sales representative or the factory for more information.