Graphtec America GL800 Data Loggers Recorders Plotters
Follow us for the latest equipment specials.
New Graphtec America GL800
Call 1-800-615-8378 or 407-804-1299 for more information
Sell Equipment Repairs Add to cart E-mail this page Alert me when this goes on sale
Graphtec America GL800 Details
Graphtec America GL800
DISCONTINUED AND REPLACED BY GL820 View the New Graphtec GL820 Here
Modern conveniences such as Ethernet and USB 2.0 interfaces are included, along with a PCMCIA flash memory card port, so you can easily get the data out of your GL800 and transfer it to your computer. Data are normally captured into the GL's large internal memory, at rates selectable from 100 ms to 1/hour! You can record for hours, days, or even weeks with the 2 MS memory.
High Isolation
We built in 125 VAC RMS / 350 VDC isolation on all the analog channels, for a few reasons. First, it means you can hook up your GL midi LOGGER without the normal worry about ground loops, providing you more flexibility and control. Second, it just makes good technical sense to isolate the inputs, and is even a nice safety feature. Few products in this class provide this kind of isolation as standard...or even as an option!With its dedicated USB port for flash drives, the GL800 makes it easy to transfer data on to your PC or laptop for direct processing.There are models from SanDisk and other companies which adapt CF, MemoryStick, SD, and a variety of flash media to your Graphtec data logger!
Main Features
- The GL800 has a built-in 5.75" TFT color LCD display
- Built-in Ethernet and USB 2.0 interfaces
- Compact 7.6”x4.8” and approx weight of 1lb
- Direct recording to USB memory sticks, up to 1GB
- 12MB Built-in Non-volatile memory retains data even after the GL800 is turned off
- Voltage( 20mV to 50V), Temp Thermo-couplers (K, E, J, T, N, R, S, T, B, W) and Humidity
- Up to 200 Multi-function PhotoMOS relay isolated input channels
- Optional battery pack provides up to 9 hours of continuous recording
- Battery also functions as a UPS in the event of AC power failure
- 16-bit A/D converters (14-bit processing)
- Max Sample rate of 10 Samples/second
- Statistical analysis functions
Options and Upgrades
- B-537 Extension terminal base kit
- B-538 20 channel extension terminal set
- B-517 Battery pack
- B-530 Humidity sensor
- B-513 Logic/Alarm cable
- B-514 DC power cable