Rohde & Schwarz FSL6.16
Base Frequency: 9 KHz Max Frequency: 6 GHz
Spectrum Analyzer, 9 kHz to 6 GHz, with Tracking Generator
Rohde & Schwarz, Inc. FSL616 Spectrum analyzer 9 kHz - 6 GHz -135 - +20 dBm, RBW 300 Hz - 10 MHz With Tracking Generator 1 MHz - 6 GHz (P/N 1300.2502.16)
The Rohde & Schwarz, Inc. FSL616 spectrum analyzer is a wide band, very sensitive receiver. It works on the principle of "super-heterodyne receiver" to convert higher frequencies (normally ranging up to several 10s of GHz) to measurable quantities. The received frequency spectrum is slowly swept through a range of pre-selected frequencies, converting the selected frequency to a measurable DC level (usually logarithmic scale), and displaying the same on the CRT of the Rohde & Schwarz, Inc. FSL616. The CRT displays received signal strength (y-axis) against frequency ( x-axis).
Some applications for Rohde & Schwarz, Inc. FSL616 Spectrum Analyzers include Site Monitoring: Verify that the frequency and signal strength of your transmitter is accurate. Interference: Before a system is installed you use a Rohde & Schwarz, Inc. FSL616 spectrum analyzer to verify that the frequencies (you plan to use) are not occupied or if the presence of a very strong signal will interfere with your new setup. Interference can be created by a number of different situations. Other tests that utilize the Rohde & Schwarz, Inc. FSL616 spectrum analyzer features include antenna isolation, co-channel interference, adjacent channel power, occupied bandwidth, intermodulation, microwave or satellite antenna alignment, and characterization of components.
Model | SKU | Description |
---|---|---|
DCV-1 | 0240.2187.10 | Documentation of calibration values |
FSL6-DKD | 1161.2675.02 | FSL6 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
FSL-B10 | 1300.6208.02 | GPIB interface |
FSL-B22 | 1300.5953.02 | RF preamplifier gain 20 dB |
FSL-B30 | 1300.6308.02 | DC power supply 12 - 28 V |
FSL-B31 | 1300.6408.02 | NiMH battery pack |
FSL-B4 | 1300.6008.02 | OCXO reference frequency |
FSL-B5 | 1300.6108.02 | Additional interfaces video/IF-output, power meter 28 V - DC for noise source |
FSL-B6 | 1300.5901.02 | TV trigger for FSL and for ZVL with ZVL- |
FSL-B7 | 1300.5601.02 | Narrow resolution filters 10 Hz - 300 Hz |
FSL-B8 | 1300.5701.02 | Gated sweep function for FSL and for ZVL with ZVL-K1 |
FSL-K14 | 1302.0913.02 | Spectrogram measurement, application firmware for FSL and for ZVL with ZVL-K1 |
FSL-K20 | 1301.9675.02 | Application firmware for cable TV and TV measurements for R&S FSL |
FSL-K30 | 1301.9817.02 | Application firmware for noise figure and gain measurements for FSL and for ZVL with ZVL-K1 |
FSL-K7 | 1301.9246.02 | Analogue demodulation AM/FM/PM for FSL and for ZVL with ZVL-K1 |
FSL-K72 | 1302.0620.02 | 3GPP Code Domain Power measurements for base station for FSL and for ZVL with ZVL-K1 |
FSL-K8 | 1301.9398.02 | Application firmware for TX measurements acc. to Bluetooth v. 1.1 and 2.0 (EDR) for FSL and for ZVL with ZVL-K1 |
FSL-K9 | 1301.9530.02 | Power sensor measurements with NRP |
FSL-K91 | 1302.0094.02 | Application firmware for WLAN 802.11A,B,G measurements for FSL and for ZVL with ZVL-K1 |
FSL-K91N | 1308.7903.02 | Upgrade of FSL-K91 to 802.11n |
FSL-K92 | 1302.0236.02 | Application firmware for WiMAX 802.16, OFDM measurements |
FSL-K92U | 1302.0307.02 | Upgrade from FSL-K92 to FSL-K93 |
FSL-K93 | 1302.0736.02 | Application Firmware for WIMAX 802.16 OFDM/OFDMA Measurements for FSL and for ZVL with ZVL-K1 |
FSL-Z3 | 1300.5401.00 | Soft carrying bag |
FSL-Z4 | 1300.5430.02 | Additional charger unit for FSL-B31. Allows charging the battery without FSL |
EVS-Z6 | 5201.7760.00 | Accessory: Protective hard cover (for EVS300, FSL, ZVL) |
ZZA-S334 | 1109.4487.00 | Adapter for BW2000 3HU 3/4 cabinet with impact protection |
FSL6-C3 | 1300.2502.16.C3 | Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibrations |
FSL6-C5 | 1300.2502.16.C5 | Five years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibrations. |
FSL6-R3 | 1300.2502.16.R3 | Three years of depot repair coverage, including recalibration and test data if necessary to complete a repair - 1st year of repair coverage is provided by the 12-month new product warranty |
FSL6-R5 | 1300.2502.16.R5 | Five years of depot repair coverage, including recalibration and test data if necessary to complete a repair - 1st year of repair coverage is provided by the 12-month new product warranty |
FSL-B8 | 1300.5710.02 | Gated Sweep 2) |
FSL-K901 | 1302.0507.02 | First prolongation of option FSL-K0 enabling of all firmware options by further 1000 operating hours |