Fluke 5100A General Standards
Follow us for the latest equipment specials.
Refurbished Fluke 5100A
Call 1-800-615-8378 or 407-804-1299 for more information
Sell Equipment Repairs Add to cart E-mail this page Alert me when this goes on sale
Fluke 5100A Details
Fluke 5100A
MULTIFUNCTION CALIBRATOR
Need an instrument accurate enough to calibrate digital multimeters? One that will supply AC & DC Voltage, AC & DC Current and Resistance? Ease-of-use and reliability are just two reasons why you'll find the 5100A Calibrator in both calibration and personal labs. DC voltage: 0 to 1100 V on six ranges with resolutions from 0.1 ?V to 10 mV, ?(0.005% of output + 0.001% of range + 5 ?V); DC current: 10 ?A to 2 Amps on five ranges with 1 nA to 10 mA resolution, ?(0.025% of output + 0.0025% of range + 0.01 ?A). AC voltage: 1 mV to 1100 V is available at 400 Hz. The maximum voltage available varies with the frequency around the 400 Hz base, reaching a 20 V max. between 20 and 50 kHz. The ACV accuracy at 400 Hz, 50-1 kHz (up to 250 V), and 1 kHz-10 kHz (up to 110 V) is ?(0.05% of output + 0.005% of range + 50 ?V). At 10 kHz-20 kHz (up to 110 V) and 20 kHz-50 kHz (up to 19.9999 V) it?s ?(0.08% of output + 0.008% of range + 50?V). AC current: 10 ?A to 2 Amps. The ACAmps accuracy is ?(0.07% of output + 0.01% of range + 2 ?A). Resistance outputs at the cardinal values from 1 Ohms to 10 M Ohms are available. The accuracy at (four terminal): 1 Ohms is 0.02%; 10 Ohms is 0.01%; 100 Ohms, 1 k Ohms, and 10 k Ohms is 0.005%. Two terminal at 100 k Ohms is 0.005%; 1 M Ohms is 0.01%; and 10 M Ohms is 0.05%.