Rohde & Schwarz FSH4 Series Spectrum Analyzers
Follow us for the latest equipment specials.
Refurbished Rohde & Schwarz FSH4 Series
Sell Equipment Repairs Add to cart E-mail this page Alert me when this goes on sale
Rohde & Schwarz FSH4 Series Details
Rohde & Schwarz FSH4 Series
3.6 GHz Handheld Spectrum Analyzer
The new R&S FSH4/8 builds upon successes of FSH3/6/18 with network operators, TV broadcast operators, and military to offer an indispensable tool for field users who need an efficient measuring instrument. The new FSH4/8 improved upon RF performance, CPU speed, display size, interfaces for memory expansion slot to further support a very wide range of applications, and truly make it a mobile precise measurement instrument. Depending upon model and installed options, it serves as a power meter, cable and antenna tester, or a two-part vector network analyzer. With the new and improved GUI and dedicated function keys, it provides better operation to field users.
Models:
FSH4.04 = Handheld Spectrum Analyzer 9 kHz to 3.6 GHz with Preamplifier
FSH4.14 = Handheld Spectrum Analyzer 9 kHz to 3.6 GHz with Preamplifier, Tracking Generator
FSH4.24 = Handheld Spectrum Analyzer 300 kHz to 3.6 GHz with Preamplifier, Tracking Generator, VSWR bridge
Applications:
- Service & Maintenance on transmitter stations
- Cable & Antenna tests
- EMF measurements
- EMI precompliance
- Signal monitoring
- Interference hunting
- Precise power measurements
Key Facts:
- Frequency range from 9 kHz to 3.6 GHz or 8 GHz
- High sensitivity (<-141dBm(1Hz), with preamplifier<-161 dBm (1 Hz ))
- Low measurement uncertainty (<1 dB)
- Internal tracking generator and VSWR bridge with built-in DC voltage supply (bias)
- Two-port network analyzer
- Directional power measurements up to 4 GHz under operating conditions
- Easy-to-replace Li-ion battery for up to 4.5 h of operation
- Rugged, splash-proof housing for rough work in the field
- Easy handling due to low weight (3 kg with battery) and easy-to-reach function keys
- Saving of measurement results on SD card
- LAN and USB interface for remote control and transfer of measurement data
- R&S FSH4View software for simple documentation of measurement results
Key Features:
- Ease of use
- Ruggedized, yet mobile form factor
- Accessories for field users
- Improved RF performances
- Easy to replace Li-Ion battery pack with an external charger
- Internal VSWR bridge to reduce overall size and weight, making it easy to handle
- SD memory expansion slot to store measurements, results and installation settings
- USB and LAN interfaces supporting remote control functions and ease of firmware updates
- Faster CPU to provide quicker display updates
- Larger 6.5o VGA display allowing split screen mode
New Features:
- Improved RF Performance
- up to 16 dB more sensitivity, 20 dB better phase noise @10 kHz offset
- up to 0.5 dB better measurement accuracy
- Internal VSWR Bridge with two Bias-Tees
- avoids repeatedly mounting and dismounting the VSWR bridge
- reduced total size, comfortable handling for the field use
- power supply of active components like tower mounted amplifiers (TMA)
- 2-Port Vector Network Analyzer
- Magnitude and phase measurement in forward and reverse direction
- Measurement of all four S-parameters S11, S21, S12 S22
- Easy exchangeable Li-Ion battery
- extension of the battery operating time
- state-of-the-art battery technology
- (high capacity at a low weight)
- battery operating time up to 3 h (4 Ah)/ 4.5h (6 Ah)
- External battery charger available
- SD-memory card slot
- easy memory extension via ordinary SD-card
- storing of thousands measurement results and instrument settings
- easy handling of test results in security areas
- USB/LAN interfaces
- remote control via USB/LAN
- easy firmware update via LAN or USB
- Large 6.5 o color display with 640 x 480 VGA resolution
- improved resolution for distance to fault
- allows split screen mode
- Faster CPU
- automatic scrambling code detection approx. 5 times faster than FSH3
- faster display update rate -> 15/s (FSH: 8/s)
- Display of two traces measurement with different detectors
- Improved operating concept
- additional hard and soft keys leads to a more clear menu structure
- improved multi-marker operation
- GPS Receiver Option (planned)
- Support of external GPS-Receiver
- For documentation of the current location
- Improvement of the internal reverence frequency
- Built-in loudspeaker
- AM/FM AF- demodulation without headphone
- All in- and output connectors with covers
- Protection against dirt, dust and water
Model | SKU | Description |
---|---|---|
FSH-K40 | 1304.5606.02 | Remote control via LAN or USB für FSH4/8 (software license) |
FSH-K41 | 1304.5612.02 | Distance To Fault measurement for FSH4/8 (for model .24 and .28 only, |
FSH-K42 | 1304.5629.02 | Vector reflection and transmission measurement (for FSH4/8 model .24 and .28 only) |
FSH-Z28 | 1300.7810.03 | Load/short/open calibration standard for FSH4/8; DC to 8GHz, N connector |
FSH-Z29 | 1300.7510.03 | Load/short/open calibration standard for FSH4/8; DC to 4GHz, N connector |
FSH-Z320 | 1309.6600.00 | RF cable (1m), DC to 8GHz, connectors N(m)/N(f), for DTF measurements |
FSH-Z321 | 1309.6617.00 | RF cable (3m), DC to 8GHz, connectors N(m)/N(f), for DTF measurements |
HA-Z201 | 1309.6100.00 | Spare power supply including main plug (for EU, GB and USA; |
HA-Z202 | 1309.6117.00 | 12V car adapter. Connector for cigarette lighter (for PR100, FSH4/8 and ETH) |
HA-Z203 | 1309.6123.00 | Battery charger for lithium-ion battery pack 4.5AH/6.75AH (for PR100, FSH4/8 and ETH) |
HA-Z206 | 1309.6146.00 | LI-ION Battery pack 6.75Ah (for PR100, FSH4/8 and ETH) |
HA-Z210 | 1309.6152.00 | Spare Ethernet cabel 2m; (for PR100, FSH4/8 and ETH) |
HA-Z211 | 1309.6169.00 | Spare USB cable 1.8m, standard/mini-USB connectors (for PR100, FSH4/8 and ETH) |
HA-Z220 | 1309.6175.00 | Soft carrying bag (for PR100, FSH4/8 and ETH) |
HA-Z231 | 1309.6217.00 | SD memory card 1GB, (for PR100, FSH4/8 and ETH) |
FSH4-C3 | 1309.6000.04.C3 | Three Years Depot Calibration with test data |
FSH4-C3 | 1309.6000.14.C3 | Three Years Depot Calibration with test data |
FSH4-C3 | 1309.6000.24.C3 | Three Years Depot Calibration with test data |
FSH4-C5 | 1309.6000.04.C5 | Five Year Depot Calibration with test data |
FSH4-C5 | 1309.6000.14.C5 | Five Years Depot Calibration with test data |
FSH4-C5 | 1309.6000.24.C5 | Five Years Depot Calibration with test data |
FSH4-R3 | 1309.6000.04.R3 | Three Years Depot Repair Coverage |
FSH4-R3 | 1309.6000.14.R3 | Three Years Depot Repair Coverage |
FSH4-R3 | 1309.6000.24.R3 | Three Years Depot Repair Coverage |
FSH4-R5 | 1309.6000.04.R5 | Five Years Depot Repair Coverage |
FSH4-R5 | 1309.6000.14.R5 | Five Years Depot Repair Coverage |
FSH4-R5 | 1309.6000.24.R5 | Five Years Depot Repair Coverage |
DCV-1 | 0240.2187.06 | Documentation of calibration values |
DCV-1 | 0240.2187.10 | Documentation of calibration values |
FSH-Z25 | 1145.5896.02 | Soft carrying bag for FSH3/6/18 |