Rohde & Schwarz URE2
Characteristics
URE2 is a broadband RMS voltmeter featuring extremely high accuracy and speed. A patented rectifier circuit allows measurement of signals with a crest factor of up to 7 and frequencies of up to 25 MHz.
Fields of application
- Level measurements in audio range
- Interference measurements on switch-mode power supplies
- Measurement of extremely fast dialling signals and detection of simultaneously transmitted supply voltages in radiotelephony
- Automatic quality control of audio and video tapes
- High-frequency measurements in digital magnetic storage and optical data storage
- Peak weighting in video measurements (sync signals)
- Secondary calibration standard
Measurement accuracy
A patented rectifier circuit with microprocessor-controlled autocalibration makes for the outstanding measurement characteristics of URE2 and URE3. In order to further enhance the accuracy, correction factors are determined for each instrument and measurement range and stored in a nonvolatile memory.
A zero function allows noise voltages and the inherent noise to be compensated for, the measurement accuracy being thus increased in particular at low levels.
The measured frequency value is used by URE3 for an internal frequency response correction. This method increases the accuracy mainly at the higher frequencies. Distortion-free measurement of signals is ensured by:
- high input impedance
- low input capacitance
- highpass and lowpass filters that can be switched in to suppress hum or high-frequency
- noise voltages
Model | SKU | Description |
---|---|---|
DCV-1 | 0240.2187.06 | Documentation of calibration values |
URE2-C3 | 0350.5315.02.C3 | Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s). |
URE2-C5 | 0350.5315.02.C5 | Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s). |
URE2-DKD | 1161.3259.02 | URE2 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
URE2-R3 | 0350.5315.02.R3 | Three years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
URE2-R5 | 0350.5315.02.R5 | Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |