Text For Info, USA Phones only


New Time Electronics 1090


Time Electronics 1090

Request Information
New
Time Electronics 1090 Temperature and Process Calibrator w/ Factory Certificate

  • Measure/Simulate 8 thermocouples
  • Measure/Simulate PT100
  • ITS 90 standard
  • Measure/Source (uV/mV/mA)
  • Display in degrees C and degrees F
  • Automatic CJC - selectable
  • 10 point memory recall
  • Inching and Step functions
  • Mains/Battery + auto power down
  • Process loops 4-20mA and 0-50mA

    Description:

    The 1090 is a portable high performance process calibrator that combines source and measurement functions for thermocouples, PT100s, uV, mV, and mA.

    Thermocouple measurement and simulation
    The unit can measure and simulate the temperature and mV characteristics of J, K, T, R, S, B, N and E thermocouples.

    Cold junction compensation
    The unit can be operated with or without internal cold junction compensation.

    PT100 measurement and simulation
    Based on 0.3850 alpha probe standard.
    Range is 200 degrees C to 700 degrees C.

    Measurement and Source (uV, mV, and mA)
    Measurement ranges are 0 to +/-30mV and 0 to +/-60mA.
    Source ranges are 0 to +/-80mV and 0 to +80mA.

    Temperature units selection
    The display can be easily changed from degrees C to degrees F. The equivalent uV (thermocouples) and ohms (PT100) can also be shown.

    24V Process Loop drive mode
    A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source mode and setting it at 60mA (or a lower level if required).

    Inching (Incrementing/Decrementing)
    The unit has a general-purpose inching function. This adjusts the output in fixed increments of temperature (thermocouples only) or voltage or current. The set-up menu gives a the user a choice of three levels of increment i.e. 0.1, 1 or 10 for degrees C/ degrees F, or 1, 10, or 100 uV/uA for voltage/current. The lowest of these represents the highest setting resolution and provides the most precise control of the output. This is especially useful for calibrating thermostat controllers that have tight specification on hysteresis.

    Memory recall and step/auto-step functions
    Up to 10 values can be stored in the unit s non- volatile memory and they can be recalled at any time. The user can also manually step through them in sequence using the step key. Continuous stepping (auto-step) is also available at any user selectable rate between 1 and 10 seconds/step.

    Power is via an internal high capacity re-chargeable metal hydride battery that can be re-charged from an external mains charger (supplied as standard). The unit is supplied in a robust case with a carrying strap. A pocket for the instruction manual is provided.

  • NIST/UKAS Calibration Certificates can be provided at an additional charge.



    Time Electronics 1090 datasheet & specifications

    REQUEST QUOTE
     
    What product are you interested in?
     *
    Your Name
    *
    Your Company
    *
    Email
    *
    Verify Email
    *
    Telephone
    Fax
    Country
    *
    State
    Address
    City
    Zipcode
    Referral
    Additional Comments