Text For Info, USA Phones only


Refurbished Agilent 66309D-004


Agilent 66309D-004

Request Information
Refurbished

Dual Output Mobile Comm. DC Source w/ DVM

The Agilent Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and an Agilent-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.

The Agilent 66309D dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a half rack box) and eliminates the need for two separate power supplies.The 66309D dc source provides all of the capabilities of the 66309B with the addition of a built in digital voltmeter.

Options:
Option 004 = High mode default setting
Option 007 = Extra 5-pin output connectors 2
Option 0L1 = English Printed Users Guide (full documentation on CD-ROM)
Option 100 = DC power supply 87-106VAC operation, 50/60Hz
Option 120 = DC power supply 104-127VAC operation, 50/60Hz
Option 1CM = Rackmount Kit with blank filler panel
Option 220 = DC power supply 191-233VAC operation, 50/60Hz
Option 230 = DC power supply 209-254VAC operation, 50/60Hz
Option 521 = Add solid state output disconnect relays
Option A6J = Certificate of calibration - ANSI/NCSL Z540, printed
Option AXS = Rackmount Kit for side by side mounting

New Page 1

Output Ratings

  • Voltage: 0 to 15 V
  • Current: 0 to 3 A
  • Peak Current for up to 7 ms: 5 A

Programming accuracy at 25 degrees C +/-5 degrees C

  • Voltage: 0.05%+ 10 mV
  • + Current: 0.05%+ 1.33 mA

DC Readback Accuracy

  • Voltage: 0.03% + 5 mV
  • Current (+20 mA to + rated current): 0.2% + 0.5 mA
  • Current (-20 mA to rated current): 0.2% + 1.1 mA
  • Current (-20 mA to + 20 mA range): 0.1% + 2.5 MicroA

Transient Response

  • 70 mV drop, <35 Micros transient response time

 


Agilent 66309D-004 datasheet & specifications